FC-4G to SATA-II (3Gbps) RAID subsystem
Eight (8) FC-4G host ports w/ onboard bypass
Redundant, active-active RAID controllers
Hardware RAID6 XOR by dedicated ASIC400 chipsets
Intelligent load-balancing; internally & between host links by the EonPath™ multi-path software
Proactive parity and media error manual and scheduled scan/repair
High-availability, modular enclosure design
Adaptive writer policy
Up to 2GB cache per controller
Host Interface
Drive Interface
Model
Form Factor
FC-4G x 8
SATA-II (3Gbps)
A16F-R2431
3U rack-mount
RAID Controller
Hardware RAID parity computing
Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
RAID Migration
Configurable stripe size and write policy per array
Multiple Global, Dedicated, & Enclosure-specific hot-spares
Intelligent Drive Handling:
In degraded mode: skips irreparable blocks to continue rebuild
In normal operation: data-block verification and repair
Host Interface
Eight (8) FC-4G host port w/HUB functions
Concurrent I/O commands
Tagged command queuing up to 256
Adaptive cache write policies
Drive Interface
Sixteen (16) 3.0Gbps SATA-II (3Gbps) , hot-swappable drive trays
Accommodates 1-inch pitch, 3.5-inch SATA-II (3Gbps) disk drives
S.M.A.R.T. and NCQ support· Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
System Components
Heavy duty 3U enclosure
Dual-redundant RAID controller modules
One (1) 512MB DDR RAM DIMM module (default, supports up to 2GB in size) on each controller
Two (2), hot-swappable, redundant, 530W power supply units
Two (2), redundant, dual-speed cooling modules
Sixteen (16), hot-swappable drive trays
Two (2) forearm handles
LCD keypad panel
Li-Ion, life expectancy & charge level aware battery backup unit (BBU)
Management
COM1 serial port for local access to firmware-embedded utility
COM2 for UPS connection
GUI, Telnet, and SSH system monitoring via Ethernet
Java-based SANWatch software with Snapshot protection
Firmware-embedded manager via RS-232C (audio jack) that is platform independent
Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
LCD keypad panel to all configuration options
Variable logical drive options per DIMM size
Module status LED indicators:
Two (2) per drive tray
Seven (7) per controller module
One (1) per power supply unit
One (1) per BBU module
Two (2) per cooling module
Module failure alert through I 2 C bus
Interfaces
One (1) Fast Ethernet management port
Two (2) serial COM port (38400, n, 8, 1)
Power Supply Module Two (2) redundant hot-swappable power supplies with PFC
Input
100~240VAC with 530W PFC (auto-switching)
47 to 63Hz
Output
(Maximum output: 530 Watts)
+12.0V
30A max.
+ 5.0V
32A max.
+ 3.3V
32A max.
Cooling Module
Two (2) redundant dual-fan cooling modules
Maximum air flow:
High speed: 90 CFM
Low speed: 70 CFM
Environmental Specifications
Operating temperature:
0º to 40ºC (35ºC w/ battery)
Non-operating temperature:
- 40º to 60ºC
Relative humidity:
5 to 95%, non-condensing
Altitude:
Operating: sea level to 12,000 ft
Non-operating: sea level to 40,000 ft
Dimensions:
Chassis without handles: 445(W) x 130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm (19 x 5.2 x 19.9 inches)
Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
System weight:
Net weight: 28kg
Gross weight: 31kg (without drives)