S16F-R1430
S16F-G1430
The S16F-R/G1430 combines extensive Fibre Channel connectivity with the latest SAS-interface disk drives. With a compatible interface, both the high-performance SAS and cost-effective SATA-II disk drives can apply in the same array. With the SAS multi-lane expansion ports, arrays can be expanded with up to 64 more HDD.
product review
product review
Dual-active or single controller
4G FC to SAS or SATA-II (3Gbps) disk drives
Eight (8 - R1430) or four (4-G1430) 4G FC host ports
Hardware RAID5 and RAID6 engine by dedicated ASIC400 chipsets
EonPath™ multipathing sotware
SANWatch® storage management software
See details about expansion enclosures:
Host-to-Drive Interface
Model
Configuration
SAS Exp.
Form Factor
4G FC-to-SAS/SATA
S16F-R1430
Redundant
2
3U Rack-mount
4G FC-to-SAS/SATA
S16F-G1430
Single
1
3U Rack-mount
RAID Controller
Hardware RAID parity computing
Hardware RAID5 & RAID6 parity computation
Supports RAID 0, 1 (0+1) , 3, 5, 6, 10, 30, 50, 60, and NRAID
RAID Migration
Configurable stripe size and write policy per array
Multiple Global, Dedicated, & Enclosure-specific hot-spares
Intelligent Drive Handling:
In degraded mode: skips irreparable blocks to continue rebuild
In normal operation: data-block verification and repair
Host Interface
Eight (8-R1430) or four (4-G1430) 4G FC
4Gb/s via short-/long-wavelength LC-type SFP
Concurrent I/O commands
Tagged command queuing up to 1024 Max
command queue up to 1024
Fault-tolerant host links via onboard bypass
Drive Interface
Sixteen (16) 3.0Gbps SAS, hot-swappable drive trays
Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
S.M.A.R.T. and NCQ support
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
MUX kits with port selectors for dual-controller access to SATA drives
System Components
Heavy duty 3U enclosure
Dual- (R1430) or Single (G1430) RAID and I/O management controller module
Fault-tolerant modules interfaced through a common backplane
High availability SAS domains to hard drives via expanders and port selectors
One (1) 512MB DDR DIMM module (default, supports up to 2GB in size)
Redundant, hot-swappable 530W power supply units
Redundant, dual-speed cooling modules
Sixteen (16), hot-swappable drive trays
Two (2) forearm handles
Li-Ion, life expectancy-aware battery backup unit (BBU)
Management
COM1 serial port for local access to firmware-embedded utility
COM2 for UPS connection
GUI, Telnet, and SSH system monitoring via Ethernet
Java-based SANWatch software with snapshot protection
Firmware-embedded manager via RS-232C (audio jack) that is platform independent
Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
LCD keypad panel to all configuration options
Event log in reserved space; Administrator's activity log
Variable logical drive options per DIMM size
Module status LED indicators:
Two (2) per drive tray
Seven (7) per controller module
One (1) per power supply unit
One (1) per BBU module
Two (2) per cooling module
Presence detect & thermal sensors via I2 C bus
Physical/Electrical
Interfaces
Four (4) SFP host ports for 4Gb/s DAS or SAN connections
One (1) Fast Ethernet management port
Two (2) serial COM port (38400, n, 8, 1)
Power Supply Module
Redundant hot-swappable power supplies with PFC
Input
100VAC at 9A, 240VAC at 4.5A with PFC (auto-switching)
47 to 63Hz
Output
(Maximum output: 530 Watts)
+12.0V
32A max.
+ 5.0V
32A max.
+ 3.3V
30A max
Cooling Module
Redundant dual-thermal-fan cooling modules
Maximum air flow
High speed: 90CFM
Low speed: 70CFM
Environmental Specifications
Operating temperature:
5° to 40° C (35° C if battery is applied)
Non-operating temperature:
- 40° to 60° C
Relative humidity:
5 to 95%, non-condensing
Operating altitude:
Operating: 0 to 10,000 ft
Dimensions
Without protrusions: 131H x 446.2W x 500D mm
With protrusions: 131H x 485W x 532D mm
Package dimensions: 476H x 592W x 695D mm
System weight
Net weight: 34kg
Gross weight: 32kg (without drives)
Return to top