S16F-R1430 / S16F-G1430
FC to SAS/SATA 3U/16-bay RAID
- Dual-active or single controller
- 4G FC to SAS or SATA-II (3Gbps) disk drives
- Eight (8 - R1430) or four (4-G1430) 4G FC host ports
- Hardware RAID5 and RAID6 engine by dedicated ASIC400 chipsets
- EonPath™ multipathing sotware
S12F-R1420 / S12F-G1420
FC to SAS/SATA 2U/12-bay RAID
- The best end-to-end I/O performance in RAID 5 configuration for four host channels:
- Sequential Reads: 780 MB/sec
- Sequential Writes: 521 MB/sec
- A leading technology with 2U/12-bay RAID controller
- Support two (2) 4G FC host channels on each controller
- Supports up to twelve (12) SAS/SATA disk drives
- Supports up to 2GB DDR cache memory
S12F-R1432 / S12F-G1433
FC to SAS/SATA RAID subsystem
- Two (2) 4G FC host ports per controller
- Hardware RAID6 XOR engine by dedicated ASIC400 chipsets
- 12 SAS or SATA-II (3Gbps) disk drives
- With SANWatch (the management suite especially designed for Eonstor subsystems) support
- SAS expansion port(s) can connect to up to 3 or 4 JBODs, the maximum capacity is 48TB or 60TB
- Expansion enclosure:S12S-J1002-R (for S12F-R1432) or S12S-J1000-G (for S12F-G1433)
B12F-R1430 / B12F-G1430
FC to SAS 1U/12-bay RAID
- Dual-active or single controller
- 2.5-inch SAS disk drives
- Four (R1430) or two (G1430) 4G FC host ports
- Hardware RAID5 and RAID6 engine by dedicated ASIC400 chipsets
- EonPath® multipathing software
- Expansion to SAS or SATA JBOD
S16S-R1030 / S16S-G1030
SAS to SAS/SATA 3U/16-bay RAID
- SAS to SAS/SATA-II RAID subsystem
- Redundant or single RAID controller
- EonPath® multi-pathing, load-balancing software
- 4 or 2 SAS 4x wide host ports
- Hardware RAID6 engine by dedicated ASIC400 chipsets
- Superior performance w/ uncomplicated connectivity
- 16 SAS or SATA-II (3Gbps) disk drives
- Expansion to 80TB via a 4x wide expansion port
- Corresponding JBODs:
- S16S-J1000-R (dual-controller);S16S-J1000-S(single-controller)
S12S-R1032
SAS to SAS/SATA 2U/12-bay RAID
- SAS to SAS/SATA-II RAID subsystem
- Redundant RAID controller
- EonPath multi-pathing, load-balancing software
- 4 SAS 4x wide host ports
- Hardware RAID6 engine by dedicated ASIC400 chipsets
- Superior performance w/ uncomplicated connectivity
- 12 SAS or SATA-II disk drives
- Expansion to 48TB via 4x wide expansion port
- Corresponding JBODs S12S-J1002-R (dual-controller)
S12S-G1033
SAS to SAS RAID subsystem
- Two (2) SAS 4x wide host ports
- Hardware RAID6 XOR engine by dedicated ASIC400 chipsets
- 12 SAS or SATA-II (3Gbps) (3Gbps) disk drives
- Expansion to 60 drives via one (1) 4x wide expansion port
- With SANWatch (the management suite especially designed for Eonstor subsystems) support
B12S-R1030 / B12S- G1030
SAS to SAS 1U/12-bay RAID
- Dual-active or single controller
- 2.5-inch SAS disk drives
- Four (R1030) or two (G1030) SAS multi-lane host ports
- Hardware RAID5 and RAID6 engine by dedicated ASIC400 chipsets
- EonPath® multipathing software
- Expansion to SAS or SATA JBOD
S16E-R1130 / S16E-G1130
iSCSI-to-SAS/SATA RAID subsystem
- 3U, 16-bay, iSCSI-to-SAS/SATA RAID subsystem
- 8 GbE host ports enable high performance for enterprise applications
- The SAS expansion port can connect to up to 3 or 4 JBODs, the maximum capacity is 64TB or 80TB.
- Can intermix SAS/SATA disk drives within the same enclosure
- SANWatch software, storage management suite