ES S12S-J1002-R (Legacy product)
ES S12S-J1002-R
The high-density SAS-to-SAS JBOD enclosures provide capacity expansion to the 2U-profile S12S RAID systems. The J1002-R provides fault-tolerant data links across separate SAS domains. It comes with redundant power supplies and cooling modules.
- Highlights
- Technische Daten
- Zubehör
- Expansion enclosure for SAS to SAS RAID systems
- SAS drives for high performance and high reliability
- SATA drives for low cost and high capacity applications
- Highest density, 12 drives in 2U rack space
- Redundant or single JBOD controllers
- Two (2) SAS 4x wide ports per controller
- Diagnostics LED panel
- Proprietary enclosure service via connections (in-band) with the managing RAID enclosure
- Path redundancy via separate SAS domains (S12S-J1002-R)
| Host-to-Drive Interface | JBOD Model | Corresponding RAID Subsystem(s) |
Configuration | Form Factor | |
|---|---|---|---|---|---|
| Model | Max. Connection | ||||
| SAS to SAS | S12S-J1002-R | S12S-R1032 S12E-R1132 S12F-R1432 |
3 JBODs | Redundant Expander Controllers | 2U rack-mount |
| S12F-R1840 | 6JBODs | ||||
Host Interface
- Two (2) SAS 4x wide ports per controller.
- Proprietary enclosure service via in-band methodology
Drive Interface
- Twelve (12) hot swappable SAS disk drives
- MUX kits with port selectors for dual-controller access to SATA drives
System Components
- Redundant or single JBOD controller configurations
- Fault-tolerant modules interfaced through a common backplane
- Redundant, hot swappable 460W/530W power supply units
- Redundant, dual-speed cooling modules
- LED diagnostics panel
Management
- Management of multiple enclosures via RAID firmware and/or through GUI
- Module status LED indicators:
- Six (6) on LED panel (1 service LED and 5 status LEDs)
- Two (2) per drive tray
- Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
- One (1) per power supply unit
- Two (2) per cooling module
Power Supply Module
| Specifications | |
|---|---|
| Power Consumption | 460W/ 530W (J1000-G/J1002-R) |
| Input Voltage | 100VAC @ 8A/10A or 240VAC @ 4A/5A with PFC (auto-switching) |
| Frequency | 50 to 60Hz/ 47 to 63Hz |
Cooling Module
| Specifications | |
|---|---|
| Speed | High or low rotation speed controlled by firmware |
| Max. Air Flow (each module) | J1002-R: 90CFM(high speed); 70.7CFM (low speed) |
Environmental Specifications
| Humidity | Operating: 5% to 95% (non-condensing) Non-operating: 5% to 95% (non-condensing) |
|---|---|
| Temperature | Operating: 0° to 40°C (32°F to 104°F) Non-operating: -40° to 60°C (-40°F to 149°F) |
| Altitude | Operating: Sea level to 3048m (12,000 ft.) Non-operating: Sea level to 12,192m(40,000 ft.) |
Dimensions
| Dimensions | With Forearm Handles |
|---|---|
| Height | 88mm |
| Width | 482mm |
| Length | 516mm / 522mm |
| Package dimensions: 344/390(H) x 600/575(W) x 670/780(D) mm | |
System weight
|
Net Weight |
S12S-J1002-R 15.7kg ( 34.61 pounds ) |
|---|---|
|
Gross Weight |
S12S-J1002-R 23.6kg ( 52.03 pounds ) |
Spare Parts
| IFT-9279CPSU | Power Supply Module for ES S12S-J1002-R, 530W capacity | |
|---|---|---|
| IFT-9275ECPSU | Power Supply module for ES S12S-J1000-G, 460W capacity | |
| IFT-9279CFanMod | Cooling Fan Module, for ES S12S-J1002-R | |
| IFT-9275CFanMod | Cooling Fan module, for ES S12S-J1000-G | |
| IFT-89S10J122 | SAS to SAS JBOD controller module, 2 x SAS host ports | |
| IFT-9270CmSASCab1 | SAS external, Mini SAS 4x to Mini SAS 4x (SFF-8088) cable, 50cm, for S12S-J1002-R | |
| IFT-9270CmSASCab3 | SAS external cable, MiniSAS 4X(SFF-8088) to Infiniband 4X(SFF-8470, thumbscrew type), 50 Centimeters |
Accessories
| IFT-9279CDTray | Hard disk drive tray, exclusively for the S12S-X1032 models (identified by a light-green release button). | |
|---|---|---|
| IFT-9270CmSASCab2 | SAS external, Mini SAS 4x to Mini SAS 4x (SFF-8088) cable, 120cm | |
| IFT-9272CDTrayDmy | Dummy Drive tray, Type-II bezel | |
| IFT-9279CSlider36 | Enhanced rackmount bracket assembly for EonStor S12S-J1002-R, 23" to 36" rack depth | |
| IFT-9272CESlide28 | Enhanced Slide rail assembly, for EonStor S12S-J1000-G, 21" to 28.5" rack depth | |
| IFT-9272CESlide36 | Enhanced Slide rail assembly, for EonStor S12S-J1000-G, 25.5" to 36" rack depth |
This model is discontinued; the recommended offering is EonStor DS SAN storage.
Form Factor
2U 12-bay
Environmental
- Temperature:
- Operating: 0°C to 40°C
- Non-operating: -40°C to 60°C
- Altitude:
- Operating: Sea level to 3,048 m (10,000 ft)
- Non-operating: Sea level to 12,192 m (40,000 ft)
- Relative humidity: 5% to 95% non-condensing, operating or non-operating
The “Purchase Reference” feature enables customers to request a quote from Infortrend sales representatives. Please note that actual product orders and purchases are not processed via Infortrend's website. If you wish to order and purchase Infortrend products, please contact our sales representatives directly.
Please note the following:
- The list below is based on standard worldwide shipment, models may vary by region. Infortrend sales representatives can provide more information about shipment variations in your region.
- “Default Included” means that a component is standard included in system orders. Customers may order additional units to serve as spare components.