SAS to SAS/SATA-II RAID subsystem
Redundant RAID controller
EonPath multi-pathing, load-balancing software
4 SAS 4x wide host ports
Hardware RAID6 engine by dedicated ASIC400 chipsets
Superior performance w/ uncomplicated connectivity
12 SAS or SATA-II disk drives
Expansion to 48TB via 4x wide expansion port
Corresponding JBODs:
S12S-J1002-R (dual-controller)
Model
Host Interface
Drive Interface
SAS Exp.
Controller
Form Factor
S12S-R1032
4 multi-lane wide ports (SFF-8088)
SAS / SATA-II
2 wide ports(SFF-8088)
Dual redundant
2U rack-mount
Corresponding JBODs
RAID
JBOD
Max. number
S12S-R1032
S12S-J1002-R
3
Information about supported disk drives, network components, and software compatibility, please refer
to
our VIPRoom website (for authorized dealers).
RAID
Hardware RAID5 & RAID6
Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID
RAID Migration
Configurable stripe size and write policy per array
Multiple Global, Dedicated, & Enclosure-specific hot-spares
Intelligent Drive Handling:
In degraded mode: skips irreparable blocks to continue rebuild
In normal operation: data-block verification and repair
Host Interface
4 SAS wide ports
12Gbps bandwidth (half duplex) per port
Concurrent I/O commands
Tagged command queuing up to 1024
Max. command queue up to 1024
Fault-tolerant host links with the EonPath multi-pathing software
Included cables:
S12S-R1032 – 2x Mini-SAS-to-Mini-SAS SFF-8088 120cm cables
Drive Interface
12 3.0Gbps SAS/SATA-II, hot-swappable drive trays
Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
S.M.A.R.T. and NCQ support
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
In-band enclosure service through the expansion links from expansion enclosures
Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
MUX kits with port selectors for dual-controller access to SATA drives
System Components
High density, smartly managed 2U enclosure
Dual redundant RAID controller
One DIMM module with capacities from 512MB to 2GB
Redundant, hot-swappable 530W power supply units
Redundant, dual-speed cooling modules
Twelve (12), hot-swappable drive trays
Two (2) forearm handles
Li-Ion battery backup unit (BBU), life expectancy and charge level aware
Management
COM1 serial port for local access to firmware-embedded utility
COM2 for UPS connection
Automated cache flush and caching mode operation per enclosure status
GUI, Telnet, and SSH system monitoring via Ethernet
Java-based SANWatch software with Snapshot protection
Firmware-embedded manager via RS-232C (audio jack) that is platform independent
Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
LCD keypad panel for monitoring and access to all configuration options
Variable logical drive options per DIMM size
Module status LED indicators:
Two (2) per drive tray
Seven (7) per controller module
One (1) per power supply unit
One (1) per BBU module
Two (2) per cooling module
Presence detection & thermal sensors via I2 C bus
Power Supply Module
Redundant hot-swappable power supplies with PFC
Input
100VAC at 10A, 240VAC at 5A with PFC (auto-switching)
47 to 63Hz
Output
(Maximum output: 530 Watts)
+12.0V
43A max.
+ 5.0V
25A max.
Cooling Module
Redundant dual-thermal-fan cooling modules
Maximum Air Flow
90CFM (high speed); 70.7CFM (low speed)
Environmental Specifications
Operating temperature
5º to 40ºC (35°C if battery is applied)
Non-operating temperature
- 40º to 60ºC
Relative humidity
5 to 95%, non-condensing
Operating altitude
Operating: 0 to 12,000 ft
Dimensions
Chassis without handles: 446(W) x 88(H) x 498(D) mm (17.56W x 3.46H x 19.6D inches)
Chassis with handles: 482 (W) x 88(H) x 516(D) mm (18.97W x 3.46H x 20.31D inches)
Package: 575W x 390H x 780D mm (22.63W x 15.35H x 30.7D inches)
Weight
S12S-R1032: Net weight - 18.71kg (41.16 pounds)
Gross weight – 25.9kg (56.98 pounds)
Return to top