SCSI-to-IDE / Fibre-to-IDE
IDE Line Products
With Infortrend ATA RAID series, your data is better protected when drive media errors occur. The ATA series is run by sophisticated firmware and supports all standard RAID functions. Our Media Scan and Intelligent Drive Handling capabilities are the first in ATA RAID. They guarantee data availability when media errors occur on drives or even during the rebuild mode.
Architectural Matrix
| IFT-6200 | Tower | ATA RAID Subsystems |
| IFT-6300 | Rackmount | |
| IFT-7200 | ODM/SI Board |
Tower RAID Subsystem
| SCSI--to-ATA: | 1 Gbit Fibre-to-ATA |
| 6 drive: 6200-6U3 | 6 drive: 6200-6F1 (single channel) 6200-6F1D (dual channel) |
| 8 drive: 6200-8U3 | 8 drive: 6200-8F1 (single channel) 6200-8F1D (dual channel) |
Rackmount RAID Subsystem
| SCSI-to-ATA: | 1 Gbit Fibre-to-ATA |
| 8 drive: 6300-8U3 | 8 drive: 6300-8F1 (single channel) 6300-8F1D (dual channel) |
OEM/SI Board
| SCSI-to-ATA: | 1 Gbit Fibre-to-ATA |
| 6 drive: 7200-6U3 | 6 drive: 7200-6F1 (single channel) 7200-6F1D (dual channel) |
| 8 drive: 7200-8U3 7200-8U3D | 8 drive: 7200-8F1 (single channel) 7200-8F1D (dual channel) |
Features
- 64-bit RISC-based PowerPC CPU and a dedicated XOR engine
- 32/64/128/256MB SODIMM memory; addressable to 1 GB
- OEM/SI boards - board dimensions: 7.4L x 5.59W x 0.98H inches
- Two independent 64-bit PCI buses
- Firmware in Flash ROM for easy upgrade
RAID Operation
- RAID level 0, 1(0+1), 3, and 5
- Configurable global hot spare operation
- Multi-host and multi-array configuration supported
- Drive hot swap (via SCA connectors)
- Automatic background rebuild
- Online expansion
Advanced RAID Function
- Media Scan: data stripe - media soundness check
- Intelligent Drive Handling in array degrade mode rebuild
SAN Management
- LUN Masking access control over terminal emulation, configurable filter entry variables
Drive Interface
- Drive format IDE ATA-66, ATA-100, and ATA-133 applicable
- 6 to 8 hot swap drive bays and trays
- Supports 1" high form factor
Host Interface
- SCSI-160 or 1Gbit Fibre channel
- Concurrent I/O commands
- Tagged Command Queuing up to 256
- Variable stripe size per controller (optimization for random or sequential I/Os)
- Automatic bad-block reassignment
Controls/Indicators
- Front LCD control panel for setup and configuration
- 3 drive LED indicators: power, activity, and failure
- Fan, power, temperature, and drive failure indication through RAIDWatch manager
- Built-in alarm
Management Software
- Java-based RAIDWatch manager software for Windows 2000 and Windows NT via in-band SCSI; easy customer modification of GUI elements
- Powerful NPC (Notification Processing Center) module for event notification over Email, fax, LAN broadcast, SNMP traps, etc.
- Firmware-embedded manager via RS232C (platform independent)
Physical/Electrical:
System Dimensions:
| 6-bay tower | 13.8H x 6.8W x 12.9D inches (short-tower configuration) |
|---|---|
| 8-bay tower | 16.3H x 6.8W x 13.5D inches |
| 8-bay rackmount | 3U x 18.9W x 19.3D inches (rackmount configuration - standard equipment cabinet size) |
| Interfaces | One or two pairs of 68-pin, LVD SCSI host channel on SCSI subsystems; or one to two 3-pin Fibre connectors with external DB-9 Fibre port(s) for 1Gbit Fibre subsystems, 2Gbit Fibre using a short-wave adapter, and one DB-9 RS-232C serial port (38400, n, 8, 1) for terminal connection (all configurations). |
Power supply:
- 2 redundant hot-swappable power supplies with PFC
| Input | 6 & 8 bay 90~260VAC, 47~63Hz | |||
|---|---|---|---|---|
| Output | 12V | 5V | ||
| 6 & 8 bay | 14A max. | 16A max. | 250Watts in total | |
Cooling fan:
2 redundant cooling fans in two separate modules; applicable to tower and rackmount
| 6 bay | 12V, 0.3A, 2850rpm, 34dbA5V |
|---|---|
| 8 bay | 12V, 0.23A, 2600rpm, 35dbA at 30°C |
- Operating Temperature: 5 to 40°C
- Relative Humidity: 10-95%, non-condensing
- Altitude: sea level to 10,000 ft