Dual-controller, 1U-profile, 2.5-inch SAS HDD JBOD
B12S-J1000-S:
Single-controller, 1U-profile, 2.5-inch SAS HDD JBOD
The JBOD enclosure is managed by dual or single expander controllers that distribute data flow to individual disk drives and reports enclosure operating statuses through a proprietary enclosure service via in-band protocols. The enclosure, along with other JBODs, connects to a RAID subsystem and serves as a building block of a scalable configuration.
Highlights
Technical Specifications
Accessories
Fault-tolerant JBOD in a Compact 1U Chassis:
The B12S-J1000-R/S dual-/single-controller JBOD provides you the ease of easily attaching terabytes of capacity to the B12S and B12F RAID series. The B12S-J1000 houses 2.5-inch SAS interface disk drives. With data paths routed from dual-ported SAS drives, to the SAS expanders on JBOD controllers, and to the host ports, data access is safe from single point of failure.
Thanks to the low vibration and reduced airflow requirements of 2.5-inch drives, the B12F runs with higher reliability.
Expansion Links: Expansion over SAS Wide Links:
Similar to Fibre Channel expansion loops, SAS expander technologies also enable the ease of connections when the need arises for more capacity. All you have to do is to attach the cables and use a flatblade screwdriver to select an enclosure ID by a rotary switch. The SAS WWN addresses will be automatically applied to all the disk drives.
A single-controller RAID can attach to 4 expansion enclosures (60 HDD) via SAS wide links.
A redundant-controller RAID can attach to 3 expansion enclosures. Although the maximum no. of disk drives is reduced to 48, yet fault-tolerant links can be strung between RAID and JBOD enclosures.
Total Capacity with Expansion:
Up to 9TB (Max. Capacity Configuration - using 60 2.5-inch SAS HDD in single-controller RAID and JBOD)
- or -
7.2TB (Fault Tolerance Configuration - using 48 2.5-inch SAS HDD in dual-controller RAID and JBOD)
Scalability:
Redundant-controller RAID – 3 JBOD
Single-controller RAID – 4 JBOD
1U JBOD - Up to 4 JBOD for a total of 60 HDD
Host connectivity:
2 SFF-8088 wide ports per controller
Drive connectivity:
12 SAS HDD via a passive backplane
Enclosure dimensions:
Rackmount size 1U
Dimensions
Without Chassis Ears
With Chassis Ears
Height
43.5mm (1.71 inches)
43.5mm (1.71 inches)
Width
444.8mm (17.5 inches)
483mm (19 inches)
Length
497.8mm (19.6 inches)
500.6mm (19.7 inches)
Package dimensions:
780 x 590 x 240mm
System weight:
Gross weight – 20.42kg; Net weight – 13.36kg
Input Voltage
115VAC @ 6A
230VAC @ 3A with PFC (auto-switching)
Frequency
47 to 63Hz
Power Consumption
380W (max.)
Environmental:
Humidity
Operating: 5% to 90% (non-condensing)
Non-operating: 5% to 95% (non-condensing)
Temperature
Operating: 0o to 40oC (32o F to 104o F)
0o to 35oC (32o F to 95o F, if BBU is applied)
Non-operating: -40o to 60oC (-40o F to 149o F)
Altitude
Operating: 3,658m (12,000 ft.)
Non-operating: 12,192m (40,000 ft.)
Shock (Half-sine)
Operating: 5G, half-sine, 11ms pulse width
Non-operating: 15G, half-sine, 11ms pulse width
Package: 60G, half-sine, 11ms pulse width
Vibration
(Random)
Operating: 5 to 500Hz, 0.25Grms, X/Y/Z Sine
Non-operating: 5 to 500Hz, 1.88Grms, X/Y/Z Sine
(Sine)
Operating: 5 to 500Hz, 0.2Grms, X/Y/Z Sine, 30min/sweep
Non-operating: 5 to 500Hz, 1.0Grms, X/Y/Z Sine, 30min/sweep
Acoustic Noise
65dBA boundary, 60dBA normal
Regulatory:
IEC 60068-2,
MIL-STD-810E/883E,
ISTA,
ASTM-D3332,
IPC-TM-650
IEC 1000-4
IEC 1000-3-2, IEC 1000-3-3
ISO 7779/3744
RoHS
Microsfot WHQL-Windows Server 2003
EMC
CE
EN 55022: 1998/A1: 2000/A2: 2003
EN 61000-3-2: 2000/A2: 2005
EN 61000-3-3: 1995/A1: 2001
EN 55024: 1998/A1: 2001/A2: 2003
FCC (FCC Part 15, subpart B)
BSMI (CNS 13438)
Safety
UL (60950-1: 2003)
BSMI
CNS 14336: 1993
IEC 60950-1, First Edition
Spare Parts
IFT-8ABS10J122
SAS to SAS JBOD controller module, for B12S-J1000-R and B12S-J1000-S systems, 2 x SAS SFF-8088 host connectors.
IFT-9ACPSU
Power supply module for EonStor 1U/12-bay series subsystems, 380W capacity
IFT-9ACFanMod
Cooling fan module for EonStor 1U/12-bay series subsystems
IFT-9ACDTray
Drive tray, 2.5" drive
IFT-9270CmSASCab1
SAS external cable, SAS 4x to 4x (SFF-8088), 50cm.
IFT-9ACFANG
Fan module interface board, for EonStor 1U/12-bay single controller subsystems.
Accessories
IFT-9270CmSASCab2
SAS external cable, SAS 4x to SAS 4x (SFF-8088), 120cm
IFT-9277CSlider36
Enhanced slide rail assembly for EonStor 1U/12-bay series subsystems, 24" to 36" rack depth