- Expansion enclosure for SAS to SAS RAID systems
- SAS drives for high performance and high reliability
- SATA drives for low cost and high capacity applications
- Highest density, 12 drives in 2U rack space
- Redundant or single JBOD controllers
- Two (2) SAS 4x wide ports per controller
- Diagnostics LED panel
- Proprietary enclosure service via connections (in-band) with the managing RAID enclosure
- Path redundancy via separate SAS domains (S12S-J1002-R)

| Host-to-Drive Interface | JBOD Model | Corresponding RAID Subsystem(s) |
Configuration | Form Factor | |
|---|---|---|---|---|---|
| Model | Max. Connection | ||||
| SAS to SAS/SATA II | S12S-J1000-G | S12S-G1030 | 4 JBODs | Single Expander Controller | 2U rack-mount |
| SAS to SAS/SATA II | S12S-J1002-R | S12S-R1032 | 3 JBODs | Redundant Expander Controllers | 2U rack-mount |
Specifications
Host Interface
- Two (2) SAS 4x wide ports per controller.
- Proprietary enclosure service via in-band methodology
Drive Interface
- Twelve (12) hot swappable SAS/SATA II disk drives
- MUX kits with port selectors for dual-controller access to SATA drives
System Components
- Redundant or single JBOD controller configurations
- Fault-tolerant modules interfaced through a common backplane
- Redundant, hot swappable 460W/530W power supply units
- Redundant, dual-speed cooling modules
- LED diagnostics panel
Management
- Management of multiple enclosures via RAID firmware and/or through GUI
- Module status LED indicators:
- Six (6) on LED panel (1 service LED and 5 status LEDs)
- Two (2) per drive tray
- Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
- One (1) per power supply unit
- Two (2) per cooling module
Physical/Electrical
Interface
- Host Interface: Eight (8) SMP PHYs interfaced through two (2) SAS 4x wide ports per controller.
- Drive Interface: 3Gbps SAS/ SATA II
Power Supply Module
| Specifications | |
|---|---|
| Power Consumption | 460W/ 530W (J1000-G/J1002-R) |
| Input Voltage | 100VAC @ 8A/10A or 240VAC @ 4A/5A with PFC (auto-switching) |
| Frequency | 50 to 60Hz/ 47 to 63Hz |
Cooling Module
| Specifications | |
|---|---|
| Speed | High or low rotation speed controlled by firmware |
| Max. Air Flow (each module) | J1000-G: 1.3 m3/min (high speed); 0.9 m3/min (low speed) J1002-R: 90CFM(high speed); 70.7CFM (low speed) |
Environmental Specifications
| Humidity | Operating: 5% to 95% (non-condensing) Non-operating: 5% to 95% (non-condensing) |
|---|---|
| Temperature | Operating: 0° to 40°C (32°F to 104°F) Non-operating: -40° to 60°C (-40°F to 149°F) |
| Altitude | Operating: Sea level to 3048m (12,000 ft.) Non-operating: Sea level to 12,192m (40,000 ft.) |
Dimensions
| Dimensions | With Forearm Handles |
|---|---|
| Height | 88mm |
| Width | 482mm |
| Length | 516mm / 522mm |
| Package dimensions: 344/390(H) x 600/575(W) x 670/780(D) mm | |
System weight
Net Weight |
S12S-J1000-G 17.6 kg ( 38.80 pounds); S12S-J1002-R 15.7kg ( 34.61 pounds ) |
|---|---|
Gross Weight |
S12S-J1000-G 25.5 kg ( 56.22 pounds); S12S-J1002-R 23.6kg ( 52.03 pounds ) |