The high density SAS-to-SAS JBOD enclosures house either SAS or SATA-II drives, combing the performance and connectivity benefits of SAS drives, and also having cost advantages with SATA drives. The J1000-R provides fault-tolerant links across separate SAS domains, while the J1000-S provides a single, straight-through data path.
- Highlights
- Specifications
- Accessories
- Expansion enclosure for SAS to SAS RAID systems
- SAS drives for high performance and high reliability
- SATA drives for low cost and high capacity applications
- Highest density, 16 drives in 3U rack space
- Redundant or single JBOD controllers
- Two (2) SAS 4x wide ports per controller
- Diagnostics LED panel
- Path redundancy via separate SAS domains( S16S-J1000-R)
| Host-to-Drive Interface | JBOD Model | Corresponding RAID Subsystem(s) | Configuration | Form Factor | |
|---|---|---|---|---|---|
| Model | Max. Connection | ||||
| SAS to SAS/SATA II | S16S-J1000-S | 4 JBODs | Single Expander Controller | 3U rack- mount | |
| S16F-G1840 | 6 JBODs | ||||
| S24F-G1440 | 5 JBODs | ||||
| SAS to SAS/SATA II | S16S-J1000-R | 3 JBODs | Redundant Expander Controllers | ||
| A24F-R2430 A24S-R2130 |
2 JBODs | ||||
| S16F-R1840 | 6 JBODs | ||||
| S24F-R1440 | 5 JBODs | ||||
Host Interface
- Two (2) SAS 4x wide ports per controller.
- Proprietary enclosure service via in-band methodology
Drive Interface
- Sixteen (16) hot swappable SAS/SATA II disk drives
- MUX kits with port selectors for dual-controller access to SATA drives
System Components
- Redundant or single JBOD controller configurations
- Fault-tolerant modules interfaced through a common backplane
- Redundant, hot swappable 530W power supply units
- Redundant, dual-speed cooling modules
- LED diagnostics panel
Management
- Management of multiple enclosures via RAID firmware and/or through GUI
- Module status LED indicators:
- Six (6) LED on panel (1 service LED and 5 status LEDs)
- Two (2) per drive tray
- Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
- One (1) per power supply unit
- Two (2) per cooling module
Power Supply Module
| Power Requirements | |
|---|---|
| Power Consumption | 530W |
| Input Voltage | 100VAC @ 9A 240VAC @ 4.5A with PFC (auto-switching) |
| Frequency | 47-63Hz |
Cooling Module
| Specifications | |
|---|---|
| Speed | High or low rotation speed controlled by firmware proactive mechanisms |
| Max. Airflow (each module) | High speed: 90CFM Low speed: 70.7CFM |
Environmental Specifications
| Humidity | Operating: 5% to 95% (non-condensing) Non-operating: 5% to 95% (non-condensing) |
|---|---|
| Temperature | Operating: 0° to 40°C (32°F to 104°F) Non-operating: -40° to 60°C (-40°F to 149°F) |
| Altitude | Operating: Sea level to 3,658m (12,000 ft.) Non-operating: Sea level to 12,192m (40,000 ft.) |
Dimensions
| Dimensions | With Forearm Handles (Not including rear-end protrusions) | Without Forearm Handles |
|---|---|---|
| Height | 131mm (5.2 inches) | 130mm (5.1 inches) |
| Width | 482.6mm (19 inches) | 445mm (17.5 inches) |
| Length | 504.3mm (19.8 inches) | 488.2mm (19.2 inches) |
System weight
| Net Weight | S16S-J1000-S 27kg (59.52 pounds)/ S16S-J1000-R 28kg ( 61.73 pounds ) |
|---|---|
| Gross Weight | S16S-J1000-S 29.5kg (65.04 pounds)/ S16S-J1000-R 30.5kg( 67.24 pounds) |