• Overview
  • Features
  • Specifications
  • Accessories

High-Availability SAN Delivers Great Price-Performance

Data availability is critical to any business operation. Infortrend EonStor DS storage solution features high-availability hardware designs with redundant, hot-swappable hardware components, such as RAID controllers, power supplies and cooling fans to eliminate single point of failure. Hardware RAID protection ensures data accessibility during drive failure. In the event of a power outage, Battery Backup Unit (BBU) would automatically supply power to retain cached data for up to 72 hours. To protect valuable data sets against more critical threats, EonStor DS also supports storage-based snapshot and volume copy/mirror. Data availability can be achieved with minimal downtime in case of human errors or data volume failure by employing the EonStor DS snapshot and volume copy/mirror features. Leveraging Infortrend's world class RAID engine and Fibre Channel protocol, EonStor DS storage solution delivers breakthrough performance for today's online applications and economy.

Intuitive and Easy Management

Storage management should be simple. The EonStor DS storage solution includes a comprehensive management software suite, SANWatch, to centrally manage multiple EonStor DS subsystems over a standard TCP/IP network. EonStor DS status and event information summary can be viewed on the portal window. Necessary functions to configure, manage and monitor the EonStor DS are only a few clicks away. Besides providing all firmware features through a user-friendly GUI, SANWatch also supports script-based configuration of multiple EonStor DS subsystems simultaneously. Automatic critical event notifications can be customized to suit the most critical storage environment. SANWatch will guide users through initializing, configuring and maintaining the EonStor DS every step of the way.

Flexible Scalability

The EonStor DS storage solution supports dynamic scaling to aid in the planning for future storage growth while satisfying the current storage needs. Flexible drive type and capacity support (SAS, SATA and various drive sizes) allows for the accommodation of current application needs while future proofs to support tomorrow's applications. EonStor DS S12F storage solution can be expanded up to 60 drives to meet the proliferation of storage growth. The "scale as you grow" flexibility of the EonStor DS storage solution minimizes the upfront investment and provides the best overall Total Cost of Acquisition (TCA).

High Energy Efficiency

Contributing to environmental sustainability, the EonStor DS storage solution enables energy cost-savings while maintaining performance. It is equipped with power saving designs such as high efficiency power supplies and intelligent multi-level drive spin-down technology.

Features Benefits

Data protection:

  1. Snapshot
  2. Volume copy/Volume Mirror
Support the highest data availability and quick service restart after storage accidents
Two 4Gb/s Fibre Channel host ports per controller
  1. Best-of-class throughput power, ideal fit for bandwidth-demanding applications
  2. Backward compatible with 2G or 1G speeds, protecting current infrastructure investment
Fault-tolerant hardware modules Redundant controllers, PSUs, fans; high-availability hardware design, preventing "Single-Point-of-Failure"
Drive interface: SAS or SATA-II disk drives Allow data of different values to be stored in different storage tiers, enabling the best ROI
Maximum expansion of 4 JBODs via multi-lane SAS links, up to 60 HDDs in total "Pay-as-you-grow" scalability; no waste on what you dont need, and no worries about what you will need
Powerful management suite, SANWatch, support, including multi-pathing functions
  1. Easy management and monitoring of your subsystems anywhere, locally or remotely
  2. Recognize and manage redundant paths; support path failover and load-balancing
Multiple monitoring methods Real-time problem detection and notification to enable proactive error handling
Intelligent multi-level drive spin-down technology In spin-down state, drives can save up to 60% of energy consumption
Host Connectivity
  1. Two (2) 4Gb/s FC ports on each controller
  2. Concurrent I/O commands
  3. Maximum tagged command queuing: 1024
Drive Connectivity
  1. 3Gbps SAS or SATA-II, up to twelve (12) drives per system
  2. Accommodates 1-inch pitch, 3.5-inch disk drives
  3. S.M.A.R.T. support
  4. NCQ support
  5. Automatic bad-sector reassignment
  6. Dedicated bandwidth to each connected drive
  7. Drive buffer on/off switch
Supported Drives
  1. 1TB or 2TB - 3.5" 7,200 RPM 3Gb/s SATA drives
  2. 300GB or 450GB - 3.5" 15,000 RPM 3Gb/s SAS drives
  3. 450GB or 600GB - 3.5" 15,000 RPM 6Gb/s SAS drives
Controller Single
Drive Expansion Ports One (1) 3Gb/s SAS 4x wide port
Expansion Enclosure (JBOD) ESDS S12S-J1000-G
Max. Drives (via JBOD) 60
Data Protection (optional) Snapshot, Volume Copy/Mirror
RAID functionality
  1. Global, Dedicated or Enclosure hot-spare
  2. RAID levels supported: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60
  3. Online expansion by:
    1. Adding new drives
    2. Copying and replacing drives with drives of larger capacity
  4. RAID migration
  5. Configurable stripe size and write policy per array
  6. Intelligent drive handling:
    1. In degraded mode: skips irreparable blocks to continue rebuild
    2. In normal operation: data-block verification and repair
Management
  1. Java-based SANWatch management software with multi-pathing support (EonPath)
  2. COM1 serial port for local access to firmware-embedded utility
  3. Automated cache flush and caching mode operation per enclosure status
  4. GUI, Telnet, and SSH system monitoring via Ethernet
  5. Platform-independent firmware manager
  6. Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
  7. LCD keypad panel for monitoring and access to all configuration options
  8. Module status LED indicators:
  9. Component presence detection & thermal sensors via I2C bus
Green Designs
  1. High-efficiency power supplies
  2. Intelligent multi-level drive spin-down
System Components
  1. One (1) RAID controller module
  2. One (1) 1GB DIMM module, upgradable to 2GB(*)
  3. Two (2) redundant 350W power supply units
  4. Two (2) redundant cooling modules
  5. Twelve (12), hot-swappable drive trays
  6. One (1) optional Li-Ion Battery Backup Unit (BBU)
* The default capacity of DIMM modules may vary by region; please contact our sales representatives for details.
Dimensions

88(H) x 446(W) x 490 (D) mm

Power
  1. Power supplies: Two 350W
  2. AC voltage: 100VAC @ 6A/ 240VAC @ 3A with PFC (auto-switching)
  3. Frequency: 47-63 Hz
Environmental
  1. Temperature: -10 to 70° C operating/ -20 to 70° C non-operating
  2. Altitude: Sea level to 12,000ft operating / sea level to 40,000ft non-operating
  3. Relative humidity: 5 to 95% non-condensing, operating and non-operating
Weight
  1. Net weight: 18.71kg
  2. With HDDs: 28.91kg
Service and Support
Standard Service
  1. 3-year limited hardware/software warranty and 8x5 phone, web and email support
Upgrade/Extension Options
  1. Replacement part dispatch on the next business day (up to 5 years)
  2. Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day (up to 5 years)
  3. Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours (up to 5 years)
  4. Extended Standard Service up to 5 years

Spare Parts

Null modem IFT-9011 Null Modem, DB9 female to DB9 male, wires swapped
RS-232C cable IFT-9270ASCab RS-232C serial cable, audio-jack to DB9
UPS Y-cable IFT-9270CUPSYCab UPS Y-cable, 2 audio jack-to- 1 DB-9
IFT-82SF14GE12DMA RAID controller module, for ESDS S12F-G1433 subsystem, SAS Exp., 1GB DDR RAM
Cooling fan module IFT-9272CFanModE Cooling fan module, for ES 2U DDR-interface subsystems
Left-side forearm handle IFT-9272CHandLLCD Left-side forearm handle, for ES 2U series subsystems, LCD panel included
Right-side forearm handle IFT-9272CHandR Right-side forearm handle, for ES 2U series subsystems
Power supply module IFT-9272CPSU Power supply module, for ES 2U DDR-interface subsystems, 350W capacity
  IFT-9373CDTray Plastic Drive tray, Type-III bezel and Type-II LED lightpipe

Accessories

Li-Ion battery cell pack IFT-9273CBTE Battery cell pack, Li-Ion, for ES Enhanced 3U/16-bay subsystems, BBU ID, high capacity
IFT-9270CFCCab01 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter
IFT-9270CFCCab02 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meters
IFT-9270CFCCab03 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meters
IFT-82SF14GE12DMB RAID controller module, for ESDS S12F-G1433 subsystem, SAS Exp., 2GB DDR RAM
1G DDR DIMM module IFT-DDRESCMA 1GB DDR DIM module for all EonStor subsystems
1G DDR DIMM module IFT-DDRESCMB 2GB DDR DIM module for all EonStor subsystems
IFT-9270CSFP2GA01 Avaya Fibre Channel 2.125 / 1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode
IFT-9270CSFP4GA01 Avaya Fibre Channel 4.25 / 2.125 / 1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode
IFT-9272CESlide28 Enhanced Slide rail assembly, for ES 2U series subsystem, 21"~28.5" rack depth
IFT-9272CESlide36 Enhanced Slide rail assembly, for ES 2U series subsystem, 25.5"~36" rack depth
  IFT-SOFT-DRSDS Local Replication software license for EonStor DS series.