• Overview
  • Features
  • Specifications
  • Accessories

High-Availability SAN Delivering Great Price-Performance

Data availability is critical to any business operation. The Infortrend EonStor DS storage solution features high-availability hardware designs with redundant, hot-swappable hardware components, such as RAID controllers, power supplies and cooling fans to eliminate single point of failure. Hardware RAID protection ensures data accessibility during drive failure. In the event of a power outage, CacheSafe technology will automatically leverage the Battery Backup Unit (BBU) to safeguard cached data by writing it to the flash module for permanent retention. To protect valuable data sets against more critical threats, EonStor DS also supports storage-based snapshots and volume copy/mirror. In case of human errors or data volume failure, data availability can be achieved with minimal downtime by employing the EonStor DS snapshot and volume copy/mirror features. Leveraging Infortrend's world-class RAID engine and FC protocol, the EonStor DS storage solution delivers breakthrough performance for today's online applications and economy.

Flexible Scalability

The EonStor DS storage solution supports dynamic scaling to aid in the planning for future storage growth. Flexible drive type and capacity support (SAS, SATA and various drive sizes) satisfies current applications and enables you to accommodate future needs. Through expansion enclosures, a 12-bay EonStor DS storage solution can be expanded to a maximum of 84 drives to meet the proliferation of storage growth. The "scale as you grow" flexibility of the EonStor DS storage solution minimizes the upfront investment and provides the best overall Total Cost of Acquisition (TCA).

Intuitive and Easy Management

Storage management should be simple. The EonStor DS storage solution includes a comprehensive management software suite, SANWatch, to centrally manage multiple EonStor DS subsystems over a standard TCP/IP network. EonStor DS status and event information summaries can be viewed on the portal window. Necessary functions to configure, manage and monitor the EonStor DS subsystems are only a few clicks away. Besides providing all firmware features through a user-friendly GUI, SANWatch also supports script-based configuration of multiple EonStor DS subsystems simultaneously. Automatic critical event notifications can be customized to suit the most critical storage environment. SANWatch will guide users through initializing, configuring and maintaining the EonStor DS solution every step of the way.

High Energy Efficiency

Contributing to environmental sustainability, the EonStor DS storage solution enables energy cost savings while maintaining performance. It is equipped with power-saving designs such as high-efficiency power supplies and intelligent multi-level drive spin-down.

Features Benefits

Data protection:

  1. Snapshot
  2. Volume copy/Volume Mirror
Support the highest data availability and quick service restart in case of physical or human errors
Two 4Gb/s FC host ports per controller Best-in-class throughput power; ideal fit for bandwidth-demanding applications
CacheSafe technology Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage
Fault-tolerant hardware modules Redundant controllers, PSUs, fans; high-availability hardware design, preventing single point of failure
Drive interface: 3Gb/s SAS or SATA-II disk drives Allow data of different values to be stored in different storage tiers, enabling the best ROI
Maximum expansion of 6 expansion enclosures with multi-lane SAS links, up to 84 HDDs in total "Pay as you grow" scalability
Powerful management suite support (SANWatch), including multi-pathing functions
  1. Easy management and monitoring of your subsystems anywhere, locally or remotely
  2. Recognize and manage redundant paths; support path failover and load-balancing
Multiple monitoring methods Real-time problem detection and notification to enable proactive error handling
Intelligent multi-level drive spin-down technology In spin-down state, drives can save up to 60% in energy consumption
Host Connectivity
  1. Two (2) 4Gb/s FC ports on each controller
  2. Concurrent I/O commands
  3. Maximum tagged command queuing: 1024
Drive Connectivity
  1. 3Gb/s SAS or SATA-II, up to twelve (12) drives per system
  2. Accommodates 1-inch pitch, 3.5-inch disk drives
  3. S.M.A.R.T. support
  4. NCQ support
  5. Automatic bad-sector reassignment
  6. Dedicated bandwidth to each connected drive
  7. Drive buffer on/off switch
Supported Drives
  1. 1TB or 2TB - 3.5" 7,200 RPM 3Gb/s SATA drives
  2. 300GB or 450GB – 3.5" 15,000 RPM 3Gb/s SAS drives
  3. 450GB or 600GB – 3.5" 15,000 RPM 6Gb/s SAS drives
Controller Dual redundant (ESDS S12F-R1440) or single (ESDS S12F-G1440)
Drive Expansion Ports One (1) 3Gb/s SAS 4x wide port per controller
Expansion Enclosure (JBOD)
  1. ESDS S12F-R1440: ESDS S12S-J1002-R
  2. ESDS S12F-G1440: ESDS S12S-J1000-G
Max. Drives (via JBOD) 84
Data Protection (optional) Snapshot, Volume Copy/Mirror
RAID functionality
  1. Global, Dedicated or Enclosure hot-spare
  2. RAID levels supported: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60
  3. Online expansion by:
    1. Adding new drives
    2. Copying and replacing drives with drives of larger capacity
  4. RAID migration
  5. Configurable stripe size and write policy per array
  6. Intelligent drive handling:
    1. In degraded mode: skips irreparable blocks to continue rebuild
    2. In normal operation: data-block verification and repair
Management
  1. Java-based SANWatch management software with multi-pathing support (EonPath)
  2. COM1 serial port for local access to firmware-embedded utility
  3. Automated cache flush and caching mode operation per enclosure status
  4. GUI, Telnet, and SSH system monitoring via Ethernet
  5. Platform-independent firmware manager
  6. Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
  7. LCD keypad panel for monitoring and access to all configuration options
  8. Module status LED indicators:
    1. Component presence detection & thermal sensors via I2C bus
Green Designs
  1. 80 PLUS-certified power supplies delivering more than 85% of energy efficiency
  2. Intelligent multi-level drive spin-down
System Components
ESDS S12F-R1440
  1. Two (2) redundant RAID controller modules
  2. Two (2) 1GB DIMM modules, upgradeable to 4GB(*)
  3. Two (2) redundant 530W power supply units
  4. Two (2) redundant cooling modules
  5. Twelve (12), hot-swappable drive trays
  6. Two (2) pre-installed Li-Ion battery backup unit (BBU); to implement CacheSafe technology, users have to install two (2) optional Flash Backup Module (FBM)
ESDS S12F-G1440
  1. One (1) redundant RAID controller module
  2. One (1) 1GB DIMM module, upgradeable to 4GB(*)
  3. Two (2) redundant 350W power supply units
  4. Three (3) redundant cooling modules
  5. Twelve (12), hot-swappable drive trays
  6. One (1) optional Cache Backup Module (CBM), including one Li-Ion Battery Backup Unit (BBU) and one Flash Backup Module (FBM)
* The default capacity of DIMM modules may vary by region; please contact our sales representatives for details.
Dimensions(without chassis ears/protrusions) 2U rackmount, 446mm (W) x 88mm (H) x 498mm (D)
Power
ESDS S12F-R1440
  1. Power supplies: Two (2) 530W DC
  2. AC voltage: 100VAC @ 10A / 240VAC @ 5A with PFC (auto-switching)
  3. Frequency: 47-63 Hz
ESDS S12F-G1440
  1. Power supplies: Two (2) 350W DC
  2. AC voltage: 100VAC @ 6A / 240VAC @ 3A with PFC (auto-switching)
  3. Frequency: 47-63 Hz
Environment
  1. Temperature: 0 to 40°C operating/ -40 to 60°C non-operating
  2. Altitude: Sea level to 12,000ft operating / sea level to 40,000ft non-operating
  3. Relative humidity: 5 to 95% non-condensing, operating and non-operating
Weight(without HDDs)
  1. ESDS S12F-R1440: 14.3kg
  2. ESDS S12F-G1440: 15.3kg
Service and Support
Standard Service
  1. 3-year limited hardware/software warranty and 8x5 phone, web and email support
Upgrade/Extension Options
  1. Replacement part dispatch on the next business day (up to 5 years)
  2. Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day (up to 5 years)
  3. Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours (up to 5 years)
  4. Extended Standard Service up to 5 years

Spare Parts

Battery backup unit IFT-9373CBBU Battery backup unit, Li-Ion, for EonStor G6 series subsystems, BBU ID
RAID controller module IFT-85SF14RF12DMA RAID controller module, for ESDS S12F-R1440 subsystem, SAS Exp., CBM, 1GB DDR II RAM
RAID controller module IFT-82SF14GF12DMA RAID controller module, for ESDS S12F-G1440, 1GB DDR-II RAM
Left-side forearm handle IFT-9272CHandLLCD Left-side forearm handle, for ES 2U series subsystems, LCD panel included
Right-side forearm handle IFT-9272CHandR Right-side forearm handle, for ES 2U series subsystems
Power supply unit IFT-9373CPSU Power supply unit for EonStor G6 2UR/12-bay and 3U/16-bay subsystems, 530W capacity (for S12F-R1840-4)
Drive tray (Type-III bezel and Type-II LED lighpipe) IFT-9373S1DT2S1S Plastic Drive tray (Type-III bezel and Type-II LED lightpipe), 2 SAS-to-1 SATA (SATA-II) MUX conversion, active-active port selector embedded, dual-controller subsystems, Rev. 1.2

IFT-9273CSLIDER36

Slide rail assembly, for all EonStor G6 subsystems, 24"~36" rack depth
  IFT-9373CDTray Plastic Drive tray, Type-III bezel and Type-II LED lightpipe

Accessories

IFT-9373CBBU Battery backup unit, Li-Ion, for EonStor G6 series subsystems, BBU ID
Cache backup module IFT-9373CCBM Cache backup module, Li-lon, Flash, for EonStor G6 series subsystems, BBU ID
  IFT-9373CFBM Flash backup module, for EonStor G6 series subsystems
Optical FC cable IFT-9270CFCCab01 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter
Optical FC cable IFT-9270CFCCab02 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meters
Optical FC cable IFT-9270CFCCab03 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meters
SAS external cable

IFT-9270CmSASCab3

SAS external cable, MiniSAS 4X(SFF-8088) to Infiniband 4X(SFF-8470, thumbscrew type), 50 Centimeters.
SAS external cable

IFT-9270CmSASCab4

SAS external cable, MiniSAS 4X(SFF-8088) to Infiniband 4X(SFF-8470,thumbscrew type), 120 Centimeters.
SAS external cable

IFT-9270CmSASCab5

SAS external cable, MiniSAS 4X(SFF-8088) to Infiniband 4X(SFF-8470,thumbscrew type), 170 Centimeters.
IFT-9373ASCAB RS-232C cable, DB9 to DB9
  IFT-9373CF4HIO2 Fibre to SAS/SATA host board, for EonStor/EonStor DS models, 2 x FC 4G SFP host connectors
RAID controller module IFT-85SF14RF12DMB RAID controller module, for ESDS S12F-R1440 subsystem, SAS Exp., CBM, 2GB DDR II RAM
RAID controller module IFT-85SF14RF12DMC RAID controller module, for ESDS S12F-R1440 subsystem, SAS Exp., CBM, 4GB DDR II RAM
RAID controller module IFT-82SF14GF12DMB RAID controller module, for ESDS S12F-G1440, 2GB DDR-II RAM
RAID controller module IFT-82SF14GF12DMC RAID controller module, for ESDS S12F-G1440, 4GB DDR-II RAM
IFT-DDR2RECMA 1GB DDR-II DIM module for EonStor G6 subsystems
IFT-DDR2RECMB 2GB DDR-II DIM module for EonStor G6 subsystems
IFT-DDR2RECMC 4GB DDR-II DIM module for EonStor G6 subsystems
HDD dongle board IFT-9273S1N2S1S HDD dongle board, 2 SAS-to-1 SATA (SATA-II) MUX conversion, active-active port selector embedded, dual-controller subsystems, 5V only, Rev. 1.2
IFT-9270CSFP4GA01 Avaya Fibre Channel 4.25 / 2.125 / 1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode
  IFT-SOFT-DRSDS Local Replication software license for EonStor DS series.
  IFT-9373CDTray Plastic Drive tray, Type-III bezel and Type-II LED lightpipe