- 4G FC-to-FC RAID subsystem
- Twelve (12) or eight (8) 4G FC SFP ports
- Hardware RAID6 XOR engine by dedicated ASIC400 chipsets
- Dual-/single-RAID controller configurations
- Dedicated SATA 18Gb/s RCC (Redundant Controller Communications) channels
- Sixteen (16) 4Gb/2Gb Fibre Channel disk drives
- Corresponding F16F-J4000-R/S loop-switched SBODs
See details about expansion enclosures:
F16F-J4000-R (SBOD)
| Host-to-Drive Interface | Models | Configuration | Form Factor | Fibre Ports | No. of Channels |
|---|---|---|---|---|---|
| Fibre-to-Fibre | F16F-R4031-6 | Redundant controller | 3U Rack-mount | 12 | 6 |
| Fibre-to-Fibre | F16F-R4031-4 | Redundant controller | 3U Rack-mount | 8 | 4 |
| Fibre-to-Fibre | F16F-S4031-6 | Single controller | 3U Rack-mount | 12 | 6 |
| Fibre-to-Fibre | F16F-S4031-4 | Single controller | 3U Rack-mount | 8 | 4 |
Specifications
RAID
- Hardware RAID5 & RAID6 parity computation
- Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
- RAID Migration
- Configurable stripe size and write policy per array
- Multiple Global, Dedicated, & Enclosure-specific hot-spares
- Intelligent Drive Handling:
- Intelligent Drive Handling: In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
Host Interface
- Four (4) or two (2) 4G FC channels per controller
- 32Gb/s bandwidth via separate host ports from individual controllers
- Hot-swappable I/O modules
- Concurrent I/O commands
- Tagged command queuing up to 1024
- Max. command queue up to 1024
- Fault-tolerant host links via external FC switches or the onboard hub
Drive Interface
- Sixteen (16) SCA, hot-swappable drive trays
- Accommodates 1-inch pitch, 3.5-inch 4Gb/2Gb Fibre disk drives
- S.M.A.R.T. support
- Automatic bad-sector reassignment
- Intelligent loop switch access fairness dual-loop
- Dual-loop extension via CH2 and CH3 ports
- Drive expansion via CH4 and CH5 ports
- SES enclosure service support through the expansion link
System Components
- Heavy duty 3U enclosure
- Dual-/Single- RAID controller configurations
- Fault-tolerant modules interfaced through a common backplane
- One (1) 512MB DDR DIMM per controller (default, supports up to 2GB in size)
- Redundant, hot-swappable 530W power supply units
- Redundant, dual-speed cooling modules
- Twelve (16), hot-swappable drive trays
- LCD keypad panel
- Two (2) forearm handles
- Li-Ion battery backup unit (BBU), life expectancy and charge level aware
Management
- COM1 serial port for local access to firmware-embedded utility
- COM2 for UPS connection
- GUI, Telnet, and SSH system access via an Ethernet port
- Java-based SANWatch software with snapshot protection
- Firmware-embedded manager via RS-232C (audio jack) that is platform independent
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
- LCD keypad panel to all configuration options
- Event log in reserved space
- Variable logical drive options per DIMM size
- Module status LED indicators:
- Two (2) per drive tray
- Seven (7) per controller module
- One (1) per power supply unit
- One (1) per BBU module
- Two (2) per cooling module
- Module status LED indicators:
- Three (3) per LCD panel
- Six (6) per RAID controller module
- Two (2) per Ethernet port
- One (1) per BBU module
- Two (2) per cooling module
- One (1) per PSU
- One (1) per Fibre port on I/O module
- Presence detect & thermal sensors via I²C bus
Physical/Electrical
Interfaces
- Twelve (12) or eight (8) Fibre ports each with 4Gb/s bandwidth
- One (1) Fast Ethernet management port
- Two (2) serial COM ports (38400, n, 8, 1)
Power Supply Module
Redundant hot-swappable power supplies with PFC| Input | 100VAC at 9A, 240VAC at 4.5A with PFC (auto-switching) | |
|---|---|---|
| 47 to 63Hz | ||
| Output | (Maximum output: 530 Watts) | |
| +12.0V | 32A max. | |
| + 5.0V | 32A max. | |
| + 3.3V | 30A max. | |
| Dimensions |
265 (D) x 106 (W) x 40 (H) mm (10.43 x 4.17 x 1.57 inches) | |
Cooling Module
Redundant dual-thermal-fan cooling modules| Maximum Air Flow | 90CFM (high speed); 70.7CFM (low speed) |
|---|
Environmental Specifications
| Temperature | Operating: 0° to 40°C (32° F to 104° F) (without BBU) Operating: 0° to 35°C (32° F to 95° F) (with BBU) Non-operating: - 40° to 60°C (-40° F to 140° F) |
|---|---|
| Relative humidity: | - 40° to 60°C Non-condensing : 5% to 95% |
| Altitude | Operating: 0 to 12,000 ft Non-operating: 0 to 40,000 ft |
Dimensions
Chassis without handles: 445(W) x 130(H) x 486.7(D) mm (17.5 x 5.1 x 19.2 inches) |
| Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches) |
System Weight
- Net weight: 28.5kg (62.7 pounds)
- Gross weight: 30.5kg (67.1 pounds)