Features Benefits

Thin provisioning

Ensure the most efficient allocation of pooled capacity

Data protection:

  1. Snapshot
  2. Volume copy/Volume mirror
  3. Sync and async remote replication

Support the highest data availability and quick service restart after storage accidents

Four 4Gb/s Fibre Channel host ports

High throughput and IOPS, ideal fit for IO-intensive applications

Green design:

  1. High-efficiency power supplies

  2. Intelligent multi-level drive spin-down technology

  1. 80 PLUS-certified power supplies delivering more than 80% energy efficiency

  2. In spin-down state, drives can save up to 60% of energy consumption

CacheSafe technology

Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage

Fault-tolerant hardware modules

Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure"

Expansion up to 84 HDDs

"Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need

Powerful management suite (SANWatch) support, including multi-pathing functions

  1. Easy management and monitoring of your subsystems anywhere, locally or remotely
  2. Recognize and manage redundant paths; support path failover and load-balancing

Multiple monitoring methods

Real-time problem detection and notification to achieve continuous operation

Host Ports

Four 4Gb/s Fibre Channel ports
(2 per controller)

Storage Controller

Dual redundant controllers

Cache Memory

Default 2GB, up to 8GB

** The default capacity may vary by region; please contact our sales representatives for details

Drive Connectivity

  • 3Gb/s SAS connectivity
  • Accommodates 3.5-inch disk drives
  • S.M.A.R.T. support
  • Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive

Supported Drives

  • 2.5” 10,000 RPM 6Gb/s SAS drives - 300GB, 450GB, 600GB or 900GB
  • 3.5” 15,000 RPM 6Gb/s SAS drives - 300GB, 450GB or 600GB
  • 3.5" 7,200 RPM 6Gb/s Nearline SAS drives - 1TB, 2TB, 3TB or 4TB
  • 3.5" 7,200 RPM 6Gb/s SATA drives* - 500GB, 1TB or 2TB

* MUX board required when using SATA drives

** For the latest compatibility details, please contact our sales representatives

Maximum Number of Drives

  • Per system: 12
  • Via JBOD: 84

Corresponding Expansion Enclosure

Please refer to Related Information

Form Factor

2U

RAID Functionality

  • Global, delicated or enclosure hot-spare
  • RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60
  • Online expansion by:
    • Adding new drives
    • Copying and replacing drives with drives of larger capacity
  • RAID migration
  • Configurable stripe size and write policy per system
  • Intelligent drive handling
    • In degraded mode: skips irreparable blocks to continue rebuild
    • In normal operation: data-block verification and repair

Data Services

  • Thin provisioning
  • Local replication **
    • Snapshot
    • Volume copy/ mirror
  • Remote replication*
    • Synchronous or asynchronous

* Optional
** Available with Standard license and optional Advanced license

Green Design

  • 80 PLUS-certified power supplies delivering more than 80% energy efficiency
  • Intelligent multi-level drive spin-down

Availability and Reliability

  • Redundant, hot-swappable hardware modules
  • CacheSafe technology**
  • Multi-pathing support (EonPath)
  • Device mapper support

** An optional flash backup module needs to be purchased to activate CacheSafe technology

Notification

Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and Skype. 

Management

  • Java-based SANWatch management software
  • RS232 serial port for local access to firmware-embedded utility
  • Automated cache flush and caching mode operation per enclosure status
  • Telnet and SSH system monitoring via Ethernet
  • Platform-independent firmware management GUI
  • LCD keypad panel for monitoring and access to all configuration options
  • Module status LED indicators: component presence detection & thermal sensors via I2C bus

OS Support

  • Windows Server 2003
  • Windows Server 2008, 2008 R2 (including Hyper-V)
  • RedHat Enterprise Linux
  • SUSE Linux Enterprise
  • Sun Solaris
  • Mac OS X
  • VMware
  • Citrix
  • IBM AIX
  • HP-UX

** For the latest OS support details, please contact our sales representatives.

Service and Support

  • Standard service: 3-year limited harware/software warranty and 8x5 phone, web, and email support

  • Upgrade/Extension service*:
    Replacement part dispatch on the next business day (up to 5 years)

    • Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day

    • Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours

* Optional
** Service may vary by region

Power

  • Power supplies: Two 530W DC
  • AC voltage: 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching)
  • Frequency: 47-63 Hz

Environmental

  • Temperature:
    • Operating: 0 to 40°C without BBU or CBM / 0 to 35°C with BBU or CBM
    • Non-operating: -40 to 60°
  • Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m (40,000ft) non-operating
  • Relative humidity: 5 to 95% non-condensing, operating and non-operating

Dimensions

Without chassis ears / protrusions:
440mm (W) x 90mm (H) x 500mm (D)

Weight

Without HDDs:18.10kg (39.90lbs)

Package Dimensions

779mm (W) x 564mm (H) x 597mm (D)

The “Purchase Reference” feature enables customers to request a quote from Infortrend sales representatives. Please note that actual product orders and purchases are not processed via Infortrend's website. If you wish to order and purchase Infortrend products, please contact our sales representatives directly.

 

Please note the following:

  • The list below is based on standard worldwide shipment, models may vary by region. Infortrend sales representatives can provide more information about shipment variations in your region.
  • “Default Included” means that a component is standard included in system orders. Customers may order additional units to serve as spare components. 

System

DSS12FR1440MAMUX boards (for accommodating SATA drives) includedEonStor DS FC-to-SAS 2U/12-bay ASIC667 Redundant RAID including 4xFC-4G ports, 2xSAS-3G Exp. ports, 2x1GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 12x(HDD tray+MUX board), 1xRackmount kit
DSS12FR1440MA-xxxAEonStor DS FC-to-SAS 2U/12-bay ASIC667 Redundant RAID including 4xFC-4G ports, 2xSAS-3G Exp. ports, 2x1GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 12xHDD trays, 1xRackmount kit
DSS12FR1440MBMUX boards (for accommodating SATA drives) includedEonStor DS FC-to-SAS 2U/12-bay ASIC667 Redundant RAID including 4xFC-4G ports, 2xSAS-3G Exp. ports, 2x2GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 12x(HDD tray+MUX board), 1xRackmount kit
DSS12FR1440MB-xxxAEonStor DS FC-to-SAS 2U/12-bay ASIC667 Redundant RAID including 4xFC-4G ports, 2xSAS-3G Exp. ports, 2x2GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 12xHDD trays, 1xRackmount kit
DSS12FR1440MCMUX boards (for accommodating SATA drives) includedEonStor DS FC-to-SAS 2U/12-bay ASIC667 Redundant RAID including 4xFC-4G ports, 2xSAS-3G Exp. ports, 2x4GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 12x(HDD tray+MUX board), 1xRackmount kit
DSS12FR1440MC-xxxAEonStor DS FC-to-SAS 2U/12-bay ASIC667 Redundant RAID including 4xFC-4G ports, 2xSAS-3G Exp. ports, 2x4GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 12xHDD trays, 1xRackmount kit

Hard Disk Drive/Solid State Drive/MUX Board

9373S1N2S1S-0011Required for accommodating SATA drivesMUX board, 3.5" HDD, exclusively for SAS 3G drive side dual-controller subsystems, 5V only, Rev. 1.2
H1090XB1XX1-0030HGST 2.5" SAS 6Gb/s HDD 900GB,10000RPM, 1 in 1 Packing
H72A0HA2321-0030SATA 3Gb/s HDD, 1TB, 7200RPM, 1 in 1 Packing
H72A1HA2321-0030SATA 3Gb/s HDD, 2TB, 7200RPM, 1 in 1 Packing
H72A1XS2XX1-0030Hitachi SAS 6Gb/s HDD, 2TB, 7200RPM, 1 in 1 Packing
H72A2XS2XX1-0030Hitachi SAS 6Gb/s HDD, 3TB, 7200RPM, 1 in 1 Packing
HELS72S2400-00301Seagate SAS 6Gb/s HDD, 4TB, 7200RPM, 1 in 1 Packing
HELT72S2400-00301Toshiba SAS 6Gb/s HDD, 4TB, 7200RPM, 1 in 1 Packing
HEST10S2030-00301Toshiba 2.5" SAS 6Gb/s HDD 300GB,10000RPM, 1 in 1 Packing
HEST10S2060-00301Toshiba 2.5" SAS 6Gb/s HDD 600GB,10000RPM, 1 in 1 Packing

Data Service License

SOFT-DRSDS-0010EonStor DS Advanced Local Replication License (Snapshot and Volume Copy/Mirror)
SOFT-REMDS-0010EonStor DS Remote Replication License

Expansion Enclosure

ESS16SJ1000R1EonStor SAS-to-SAS 3U/16-bay Redundant JBOD including 4 x SAS-3G ports, 2x(PSU+FAN Module), 16xHDD trays

Service & Warranty

WTE2S12R-00102-year extended warranty for ES/ESDS S12x-R and ESDS 3012R models

Cable/SFP Module

9270CFCCab04-0010Optical FC cable, LC-LC, MM-50/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter
9270CFCCab05-0010Optical FC cable, LC-LC, MM-50/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meters
9270CFCCab06-0010Optical FC cable, LC-LC, MM-50/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meters
9270CSFP4GA01-0010Fibre Channel 4.25 / 2.125 / 1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode
9373AYCAB-0010Default IncludedDB-9 Y-cable for dual-controller subsystems; maintenance-free during controller failover/failback

Controller Module

85SF14RF121DA-0010RAID controller module, for ESDS S12F-R1440 subsystem, SAS Exp., BBU, 1GB DDR-II RAM
85SF14RF121DB-0010RAID controller module, for ESDS S12F-R1440 subsystem, SAS Exp., BBU, 2GB DDR-II RAM
85SF14RF121DC-0010RAID controller module, for ESDS S12F-R1440 subsystem, SAS Exp., BBU, 4GB DDR-II RAM

Other Accessories

9373CBBU-0010Default IncludedBattery backup unit, Li-Ion, for EonStor G6 and ESDS series subsystems, BBU ID
9373CCBM-0010Cache backup module, Li-lon, Flash, for EonStor G6 and ESDS series subsystems, BBU ID
9373CDTray-0030Default Included3.5” Hard disk drive tray
9373CFBM-0010Flash backup module, for EonStor G6 and ESDS series subsystems
9373CPSU-0010Default IncludedPower supply unit w/FAN module for ES G6 /ESDS 2U-R/ESDS 3U/ESDS 3012/ESDS 3016 subsystems, 530W capacity
9373CSlider36-0010Default IncludedSlide rail assembly, for ESVA family, ESDS family and ES G6 subsystems, 24"~36" rack depth
9373S1DT2S1S-00313.5" Hard disk drive tray w/MUX board, exclusively for dual-controller subsystems v1.2
DDR2RECMA-00101GB DDR-II DIM module for EonStor G6/ESDS/ESVA subsystems
DDR2RECMB-00102GB DDR-II DIM module for EonStor G6/ESDS/ESVA subsystems
DDR2RECMC-00104GB DDR-II DIM module for EonStor G6/ESDS/ESVA subsystems